Dây Cáp Helukabel H07V-R | Chính Hãng – Single Conductors – Giá Tốt Nhất

Dây Cáp Helukabel H07V-R | Chính Hãng – Single Conductors – Giá Tốt Nhất

H07V-R

PVC-single cores, multi wire, VDE 0281 approved

Logo Image Logo Image

Technical data

  • PVC single cores to
    DIN VDE 0285-525-2-31/
    DIN EN 50525-2-31 and IEC 60227-3
  • Temperature range 
    flexing -5°C to +70°C
    fixed installation -30°C to +80°C
  • Nominal voltage 
    U0/U 450/750 V
  • Test voltage 
    2500 V
  • Insulation resistance 
    min. 10 MOhm x km
  • Minimum bending radius 
    fixed installation
    core Ø ≤ 8 mm: 4x core Ø
    core Ø > 8-1 2 mm: 5x core Ø
    core Ø > 12 mm: 6x core Ø
  • Radiation resistance 
    up to 80×106 cJ/kg (up to 80 Mrad)

Cable structure

  • Bare copper conductor, to
    DIN VDE 0295 cl.5, fine wire,
    BS 6360 cl.5, IEC 60228 cl.5
  • Core insulation of PVC
    compound type TI1 to
    DIN VDE 0207-363-3 / DIN EN 50363-3
    and IEC 60227-3
  • Core identification: see table below

Properties

  • The materials used during manufacturing
    are cadmium-free, contain no silicone
    and are free from substances harmful
    to the wetting properties of lacquers

Tests

  • PVC self-extinguishing and flame retardant
    acc. to DIN VDE 0482-332-1-2 /
    DIN EN 60332-1-2 / IEC 60332-1-2

Note

  • The following colours are recommended
    (only single colour): black, white, blue, grey,
    brown, red, orange, turquoise, violet and
    pink. Two-coloured combinations are not
    allowed, with exceptions of green-yellow.
  • Colours yellow, green, transparent only in
    (H)07V-K available.
  • Two-coloured combination is only
    permitted for (H)07V-K.

Application

These single cores are suitable for laying in tubes, under and surface mounting of plasters and also in closed installation conduits. These are not allowed to install for direct laying on cable trays, channels or tanks. These types are permitted for the inner wiring of equipment, distributor and switchboards and also for protective laying to the lightings with a nominal voltage up to 1000 V alternating current or up to 750 V direct current against earth.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.

Downloads

Data sheet 

Crosssec. mm² Outer Ø min.
max. mm
Cop. weight
kg / km
Black Green-Yellow Blue Brown Red White Grey Violet
app. RAL 9005   5015 8003 3000 9003 7001 4005
H07V-R coil
16 6,4 – 7,8 154 28825 28826 28827 28828 28829 28830 28831 28832
25 8,1 – 9,7 240 28833 28834 28835 28836 28837      
35 9,0 – 10,9 336 28838 28839 28840 28841 28842      
50 10,6 – 12,8 480 28843 28844 28845 28846 28847      
70 12,1 – 14,6 672 28848 28849 28850 28851 28852      
95 14,1 – 17,1 912 28853 28854 28855 28856 28857      
120 15,6 – 18,8 1152 28858 28859 28860 28861 28862      
150 17,3 – 20,9 1440 28863 28864 28865 28866 28867      
185 19,3 – 23,3 1776 28868 28869 28870 28871 28872      
240 22,0 – 26,6 2304 28873 28874 28875 28876 28877      
H07V-R drum
16 6,4 – 7,8 154 28185 28186 28187 28188 28189 28190 28191 28192
25 8,1 – 9,7 240 28193 28194 28195 28196 28197      
35 9,0 – 10,9 336 28198 28199 28200 28201 28202      
50 10,6 – 12,8 480 28203 28204 28205 28206 28207      
70 12,1 – 14,6 672 28208 28209 28210 28211 28212      
95 14,1 – 17,1 912 28213 28214 28215 28216 28217      
120 15,6 – 18,8 1152 28218 28219 28220 28221 28222      
150 17,3 – 20,9 1440 28223 28224 28225 28226 28227      
185 19,3 – 23,3 1776 28228 28229 28230 28231 28232      
240 22,0 – 26,6 2304 28233 28234 28235 28236 28237      

 

5/5 - (1 bình chọn)