Fluoropolymer-Insulated Wires and Cables

150°C & Lower Fluoropolymer-Insulated Wires

CASFLON™ 150 UL/cUL Style 11063
Operating Temperature: -65°C to +150°C
Operating oltage: 600V
Insulation: PF
Approval: UL

CASFLON™ 150 UL/cUL Style 1164
Operating Temperature: -65°C to +150°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ 150 UL/cUL Style 1198
Operating Temperature: -65°C to +150°C
Operating Voltage: 600V
Insulation: PTFE
Approval: UL/cUL

CASFLON™ 150 UL/cUL Style 1212/1213
Operating Temperature: -65°C to +80°C
Operating Voltage: no requirements
Insulation: PTFE
Approval: UL

CASFLON™ 150 UL/cUL Style 1331
Operating Temperature: -65°C to + 150°C
Operating Voltage: 600V
Insulation: FEP
Approval: UL

CASFLON™ 150 UL/cUL Style 1333
Operating Temperature: -65°C to + 150°C
Operating Voltage: 300V
Insulation: FEP
Approval: UL

CASFLON™ 150 UL/cUL Style 1591
Operating Temperature: -65°C to +150°C
Operating Voltage: 300V
Insulation: FEP
Approval: UL

CASFLON™ 150 UL/cUL Style 1857
Operating Temperature: -65°C to +150°C
Operating Voltage: 150V
Insulation: PFA
Approval: UL

CASFLON™ 150 UL/cUL Style 1858
Operating Temperature: -65°C to +150°C
Operating Voltage: 300V
Insulation: PFA
Approval: UL

CASFLON™ 150 UL/cUL Style 1859
Operating Temperature: -65°C to +150°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 200 UL/cUL Style 10133
Operating Temperature: -65°C to +105°C / 150°C / 200°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ NEMA HP4 Type K
Operating Temperature:  -65°C to +150°C/200°C
Operating Voltage: 600V
Insulation: extruded FEP
Approval: NEMA HP4 Type K ex. MIL-W-16878/ 11

CASFLON™ NEMA HP4 Type KK
Operating Temperature: -65°C to + 150°C/200°C
Operating Voltage: 1000V
Insulation: FEP
Approval: NEMA HP4 Type KK ex. MIL-W-16878/12

CASFLON™ NEMA HP4 Type KT
Operating Temperature:  -55°C to +150°C/200°C
Operating Voltage: 250V
Insulation: extruded FEP
Approval: NEMA HP4 Type KT ex. MIL-W-16878/13

CASFLON™ SAE AS22759 / 16
Operating Temperature:  150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

CASFLON™ SAE AS22759 / 17
Operating Temperature: 150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

200°C Fluoropolymer-Insulated Wires

CASFLON™ 200 UL/cUL Style 10086
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: ETFE
Approval: UL/cUL

CASFLON™ 200 UL/cUL Style 10133
Operating Temperature: -65°C to +105°C / 150°C / 200°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ 200 UL/cUL Style 10580
Operating Temperature: -65°C to +200°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ 200 UL/cUL Style 1180
Operating Temperature: -65°C to +200°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ 200 UL/cUL Style 1199
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: PTFE
Approval: UL

CASFLON™ 200 UL/cUL Style 1330
Operating Temperature: -65°C to + 200°C
Operating Voltage: 600V
Insulation: FEP
Approval: UL

CASFLON™ 200 UL/cUL Style 1332
Operating Temperature: -65°C to +200°C
Operating Voltage: 300V
Insulation: FEP
Approval: UL

CASFLON™ 200 UL/cUL Style 1577
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: FEP
Approval: UL

CASFLON™ 200 UL/cUL Style 1592
Operating Temperature: -65°C to +200°C
Operating Voltage: 300V
Insulation: FEP
Approval: UL

CASFLON™ 200 UL/cUL Style 1709/1929
Operating Temperature: -65°C to +200°C
Operating Voltage: 300V
Insulation: PFA
Approval: UL

CASFLON™ 200 UL/cUL Style 1710/1930
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 200 UL/cUL Style 1887
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: FEP
Approval: UL

CASFLON™ 200 UL/cUL Style 1860
Operating Temperature: -65°C to +200°C
Operating Voltage: 150V
Insulation: PFA
Approval: UL

CASFLON™ 200 UL/cUL Style 1887
Operating Temperature: -65°C to +200°C
Operating Voltage: 600V
Insulation: FEP
Approval: UL

CASFLON™ NEMA HP4 Type K
Operating Temperature:  -65°C to +150°C/200°C
Operating Voltage: 600V
Insulation: extruded FEP
Approval: NEMA HP4 Type K ex. MIL-W-16878/ 11

CASFLON™ NEMA HP3 Type E
Operating Temperature: -65°C to +200°C/260°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: NEMA HP3 Type E ex. MIL-W-16878/ 4 / 23 ex .18 awg & smaller dual rated to UL1180

250°C Fluoropolymer-Insulated Wires

CASFLON™ 250 UL/cUL Style 10142
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 10362
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 10393
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PTFE
Approval: UL

CASFLON™ 250 UL/cUL Style 10486
Operating Temperature: -65°C to +250°C
Operating Voltage: 300V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 10818
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 1570
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PTFE
Approval: UL

CASFLON™ 250 UL/cUL Style 1584
Operating Temperature: -65°C to +250°C
Operating Voltage: 1000V
Insulation: PTFE
Approval: UL

CASFLON™ 250 UL/cUL Style 1659
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PTFE
Approval: UL

CASFLON™ 250 UL/cUL Style 1726
Operating Temperature: -65°C to +250°C
Operating Voltage: 300V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 1727
Operating Temperature: -65°C to +250°C
Operating Voltage: 600V
Insulation: PFA
Approval: UL

CASFLON™ 250 UL/cUL Style 1815
Operating Temperature: -65°C to +250°C
Operating Voltage: 300V
Insulation: PTFE
Approval: UL

CASFLON™ 250 UL/cUL Style 1882
Operating Temperature: -65°C to +250°C
Operating Voltage: 150V
Insulation: PFA
Approval: UL

CASFLON™ 300 TWIN
Operating Temperature: -65°C to +300°C
Operating Voltage: 300V
Insulation: PTFE
Approval: VW-1

CASFLON™ NEMA HP3 Type E
Operating Temperature: -65°C to +200°C/260°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: NEMA HP3 Type E ex. MIL-W-16878/ 4 / 23 ex .18 awg & smaller dual rated to UL1180

CASFLON™ NEMA HP3 Type EE
Operating Temperature: -65°C to + 200°C/260°C
Operating Voltage: 1000V
Insulation: extruded PTFE
Approval: NEMA HP3 Type EE ex. MIL-W-16878/ 5 / 25 ; 18 awg & smaller dual rated to UL1180

CASFLON™ NEMA HP3 Type ET
Operating Temperature: -65°C to +200°C/260°C
Operating Voltage: 250V
Insulation: extruded PTFE
Approval: NEMA HP3 Type ET ex. MIL-W-16878/ 6 /27 ex. 18 awg & smaller dual rated to UL1180

Mil Spec Wires and Cables

CASFLON™ NEMA HP4 Type K
Operating Temperature:  -65°C to +150°C/200°C
Operating Voltage: 600V
Insulation: extruded FEP
Approval: NEMA HP4 Type K ex. MIL-W-16878/ 11

CASFLON™ NEMA HP3 Type E
Operating Temperature: -65°C to +200°C/260°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: NEMA HP3 Type E ex. MIL-W-16878/ 4 / 23 ex .18 awg & smaller dual rated to UL1180

CASFLON™ NEMA HP3 Type EE
Operating Temperature: -65°C to + 200°C/260°C
Operating Voltage: 1000V
Insulation: extruded PTFE
Approval: NEMA HP3 Type EE ex. MIL-W-16878/ 5 / 25 ; 18 awg & smaller dual rated to UL1180

CASFLON™ NEMA HP3 Type ET
Operating Temperature: -65°C to +200°C/260°C
Operating Voltage: 250V
Insulation: extruded PTFE
Approval: NEMA HP3 Type ET ex. MIL-W-16878/ 6 /27 ex. 18 awg & smaller dual rated to UL1180

CASFLON™ NEMA HP4 Type KK
Operating Temperature: -65°C to + 150°C/200°C
Operating Voltage: 1000V
Insulation: FEP
Approval: NEMA HP4 Type KK ex. MIL-W-16878/12

CASFLON™ NEMA HP4 Type KT
Operating Temperature:  -55°C to +150°C/200°C
Operating Voltage: 250V
Insulation: extruded FEP
Approval: NEMA HP4 Type KT ex. MIL-W-16878/13

CASFLON™ SAE AS22759 / 12
Operating Temperature: 260°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: MIL-W-22759/ 9 / 10 / 11 / 12

CASFLON™ SAE AS22759 /5
Operating Temperature: -65°C to + 200°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: ex. MIL-W-22759/ 5 / 6 / 7 / 8

CASFLON™ SAE AS22759 /8
Operating Temperature: 260°C
Operating Voltage: 600V
Insulation: extruded PTFE
Approval: ex. MIL-W-22759/ 5 / 6 / 7 / 8

CASFLON™ SAE AS22759 / 10
Operating Temperature: -55°C to +260°C
Operating Voltage: 1000V
Insulation: extruded PTFE
Approval: MIL-W-22759/ 9 / 10 / 11 / 12

CASFLON™ SAE AS22759 / 16
Operating Temperature:  150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

CASFLON™ SAE AS22759 / 17
Operating Temperature: 150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

CASFLON™ SAE AS22759 / 18
Operating Temperature: 150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

CASFLON™ SAE AS22759 / 19
Operating Temperature: -65°C to 150°C
Operating Voltage: 600V
Insulation: extruded ETFE
Approval: MIL-W-22759 / 16 / 17 / 18 / 19

CASFLON™ SAE AS22759 / 20
Operating Temperature: 200°C
Operating Voltage: 1000V
Insulation: extruded PTFE
Approval: MIL-W-22759 / 20 / 21 / 22 / 23

CASFLON™ SAE AS22759 / 21
Operating Temperature: 260°C
Operating Voltage: 1000V
Insulation: extruded PTFE
Approval: MIL-W-22759 / 20 / 21 / 22 / 23

Thermoplastics-Insulated Wires and Cables

Thermoplastics Insulated Wires

CASPLAST™ UL/cUL Style 1015
Operating Temperature: -30°C to +105°C
Operating Voltage: 600V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1007
Operating Temperature: -20°C to +80°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1028
Operating Temperature: -30°C to +105°C
Operating Voltage: 600V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1032
Operating Temperature: -30°C to +90°C
Operating Voltage: 1000V or 1200V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 10368
Operating Temperature: -30°C to +105°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1056
Operating Temperature: -30°C to +105°C
Operating Voltage: 600V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1095
Operating Temperature: -30°C to +80°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1569
Operating Temperature: -30°C to +105°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 1571
Operating Temperature: -30°C to +80°C
Operating Voltage: 30V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 20276
Operating Temperature: -30°C to +60 °C /80 °C
Operating Voltage: 30V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2095
Operating Temperature: -30°C to +80°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2103
Operating Temperature: -30°C to +105°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2464
Operating Temperature: -30°C to +80°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2468
Operating Temperature: -30°C to +80°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2517
Operating Temperature: -30°C to +105°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

CASPLAST™ UL/cUL Style 2651
Operating Temperature: -30°C to +105°C
Operating Voltage: 300V
Insulation: extruded PVC
Approval: UL758

Ultra-High Temperature Wires and Cables

250°C Ultra-High Temperature Wire and Cables

CASFLAM™ TGGT UL/cUL Style 5127
Operating Temperature: +250 °C
Operating Voltage: 600V
Insulation: PTFE tape with glass serve
Approval:  as per UL approvalex. as per standard UL 758 ex. RoHS Compliant

CASFLAM™ TGGT UL/cUL Style 5257
Operating Temperature: +250°C
Operating Voltage: 300V
Insulation: composites
Approval: UL/cUL (in progress)

CASFLAM™ TGGT UL/cUL Style 5196
Operating Temperature: +250°C
Operating Voltage: 600V
Insulation: composites
Approval: UL/cUL (in progress)

CASFLAM™ TGGT UL/cUL Style 5256
Operating Temperature: +250 °C
Operating Voltage: 600V
Insulation: PTFE tape with glass serve
Approval: as per UL approvalex. as per standard UL 758 ex. RoHS Compliant

450°C Ultra-High Temperature Wire and Cables

CASFLAM™ MGT 450 UL/cUL Style 5107
Operating Temperature: -60°C to +450°C
Operating Voltage: 600V
Insulation: composites
Approval: UL/cUL

CASFLAM™ MGT 450 UL/cUL Style 5128
Operating Temperature: -60°C to +450°C
Operating Voltage: 300V
Insulation: composites
Approval: UL/cUL

CASFLAM™ MGT 450 UL/cUL Style 5335
Operating Temperature: -60°C to +450°C
Operating Voltage: 600V
Insulation: composites
Approval: UL/cU

550°C & Above Ultra-High Temperature Wire and Cables

CASFLAM™ MGT 1000
Operating Temperature: +1000°C
Operating Voltage: 300 / 600V
Insulation: composites
Approval: IEC 60332

CASFLAM™ MGT 550
Operating Temperature: -60°C to +550°C
Operating Voltage: 300 / 600V
Insulation: composites
Approval: IEC 60332

CASFLAM™ MGT 550 UL/cUL Style 5561
Operating Temperature: -60°C to +550°C
Operating Voltage: 300V
Insulation: composites
Approval: UL/cUL (in progress)

CASFLAM™ MGT 550 UL/cUL Style 5562
Operating Temperature: -60°C to +550°C
Operating Voltage: 600V
Insulation: composites
Approval: UL/cUL (in progress)

CASFLAM™ MGT 750
Operating Temperature: +750°C
Operating Voltage: 300 / 600V
Insulation: composites
Approval: IEC 60332

High Temperature Coaxial Cables

Single Conductor Coaxial Cables

CASTHERMCOAX™ RG142 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1400V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG178
Operating Temperature: -55°C to +200°C
Operating Voltage: 750V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG178 U/FEP
Operating Temperature: -55°C to +200°C
Operating Voltage: 750V
Insulation: FEP / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG179 D
Operating Temperature: -55°C to +200°C
Operating Voltage: 900V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG179 D/FEP
Operating Temperature: -55°C to +150°C
Operating Voltage: 900V
Insulation: FEP / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG179 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 900V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG179 U/FEP
Operating Temperature: -55°C to +200°C
Operating Voltage: 900V
Insulation: FEP / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG180 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1400V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG302 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1700V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG303 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1400V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG304 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 3000V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG316 D
Operating Temperature: -55°C to +200°C
Operating Voltage: 1200V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG316 DFEP
Operating Temperature: -55°C to +150°C
Operating Voltage: 1200V
Insulation: FEP / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG316 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1200V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG316 U/FEP
Operating Temperature: -55°C to +200°C
Operating Voltage: 1200V
Insulation: FEP / FEP
Approval: Meets MIL-DTL-17

CASTHERMCOAX™ RG393 U
Operating Temperature: -55°C to +200°C
Operating Voltage: 1200V
Insulation: PTFE / FEP
Approval: Meets MIL-DTL-17

Silicone Wires and Cables

150°C Silicone Insulated Wires

CASLICON™ 150 UL/cUL Style 3068
Operating Temperature: -60°C to +150°C
Operating Voltage: 300V
Insulation: silicon rubber
Approval: UL

CASLICON™ 150 UL/cUL Style 3132
Operating Temperature: -60°C to +150°C
Operating Voltage: 300V
Insulation: silicon rubber
Approval: UL

CASLICON™ 150 UL/cUL Style 3529
Operating Temperature: -60°C to +150°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3530
Operating Temperature: -60°C to +150°C / 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

200°C Silicone Insulated Wires

CASLICON™ 200 UL/cUL Style 3071
Operating Temperature: -60°C to + 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3075
Operating Temperature: -60°C to + 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3122
Operating Temperature: -60°C to + 200°C
Operating Voltage: 300V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3135
Operating Temperature: -60°C to + 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3530
Operating Temperature: -60°C to +150°C / 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

Braided Silicone Insulated Wires

CASLICON™ 200 UL/cUL Style 3071
Operating Temperature: -60°C to + 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3075
Operating Temperature: -60°C to + 200°C
Operating Voltage: 600V
Insulation: silicon rubber
Approval: UL

CASLICON™ 200 UL/cUL Style 3122
Operating Temperature: -60°C to + 200°C
Operating Voltage: 300V
Insulation: silicon rubber
Approval: UL

Double Silicone Insulated Cables

CASLICON™ 200 MC SiHF-C-Si
Operating Temperature: -60°C to +180°C
Operating Voltage: 3/500 V
Insulation: silicone rubber
Approval: EN 60332-1-2 / IEC 60332-1-2

High Voltage Wires and Cables

180°C High Voltage Wires and Cables

CASVOLT™ 200 UL/cUL Style 3239
Operating Temperature: -65°C to +150°C (220°C short-time withstand)
Operating Voltage: 3KV, 6KV, 10KV, 20KV, 30KV, 40KV, 50KV
Insulation: silicone rubber
Approval: UL

200°C High Voltage Wires and Cables

CASVOLT™ 200 UL/cUL Style 3239
Operating Temperature: -65°C to +150°C (220°C short-time withstand)
Operating Voltage: 3KV, 6KV, 10KV, 20KV, 30KV, 40KV, 50KV
Insulation: silicone rubber
Approval: UL

CASVOLT™ 200 UT
Operating Temperature: -65°C to +200°C
Operating Voltage: 5KV, 15KV, 20KV, 35KV, 45KV, 60KV
Insulation: silicone rubber

250°C High Voltage Wires and Cables

CASVOLT™ 250 UL/cUL Style 1911
Operating Temperature: -65°C to +250°C
Operating Voltage: 5KV-50KV
Insulation: PFA
Approval: UL

Green Energy Wires and Cables

Electric Vehicle Wires and Cables

CASUSTAN™ EV EV 150
Operating Temperature: -40°C to +125 / 150°C
Operating Voltage: 600 VAC / 900 VDC (cross sections 6 mm²)
Insulation: TPE, XLPO
Approval: ISO 6722-1

CASUSTAN™ EV EV 180
Operating Temperature: -40°C to +180°C
Operating Voltage: 600 VAC / 900 VDC (cross sections 6 mm²)
Insulation: silicon rubber
Approval: ISO 6722-1

CASUSTAN™ EV EVP150
Operating Temperature: -40°C to +125 / 150°C, Class E according to ISO 6722-1
Operating Voltage: 600 VAC / 900, 1000 VAC / 1500 VDC
Insulation: TPE, XLPO / XLPO
Approval: ISO 6722-1

CASUSTAN™ EV FHLR2GCB2G
Operating Temperature: -40°C to +180°C, Class E according to ISO 6722-1
Operating Voltage: 600 VAC / 900 VDC, 1000 VAC / 1500 VDC
Insulation: silicone rubber
Approval: ISO 6722-1, LV 216-2

CASUSTAN™ EV FHLR91XC13X & FHLR4GC13X
Operating Temperature: -40°C to +150°C
Operating Voltage: 1000 VAC / 1500 VDC
Insulation: XLPO/EVA, TPE-E
Approval: ISO 6722-1 class D. ISO 19642-9 class D

CASUSTAN™ EV MC FHLR2GCB2G
Operating Temperature: -40°C to +180°C,
Operating Voltage: 600 VAC / 900 VDC, 1000 VAC / 1500 VDC
Insulation: silicone rubber
Approval: ISO 6722-1

CASUSTAN™ EV EVP180
Operating Temperature: -40°C to +180°C, Class E according to ISO 6722-1
Operating Voltage: 600 VAC / 900 VDC, 1000 VAC / 1500 VDC
Insulation: silicone rubber
Approval: ISO 6722-1

Photovoltaic Cables

CASUSTAN™ PV H1Z2Z2-K
Operating Temperature: -40°C to +90°C
Operating Voltage: 1.0 / 1.0 kV A.C, 1.5 / 1.5 kV D.C
Insulation: cross-linked halogen-free compound / cross-linked LSZH compound
Approval: EN 50618

Special and Custom Wires and Cables

PEEK Insulated Wires and Cables

CASPEEK™ 260
Operating Temperature: -60°C to +260°C
Operating Voltage: 600V
Insulation: PEEK

Rolling Stock Wires and Cables

CASRAIL EN50264-2-1 1800V S
Operating Temperature: -40°C to +90°C
Operating Voltage: 1.8/3kV
Insulation: fire resistant elastomer as per EN 50264-2-1
Approval: EN 50264

CASRAIL EN50264-2-1 3600V S
Operating Temperature: -40°C to +90°C
Operating Voltage: 3.6/6kV
Insulation: fire resistant elastomer as per EN 50264-2-1
Approval: EN 50264

CASRAIL EN50264-2-1 600V S
Operating Temperature: -40°C to +90°C
Operating Voltage: 0.6/1kV
Insulation: fire resistant elastomer as per EN 50264-2-1
Approval: EN 50264

CASVOLT™ NSHXAFÖ 1.8/3 kV
Operating Temperature: -40°C to +90°C
Operating Voltage: 1.8/3kV
Insulation: extruded rubber compound 3G13/LSZH Rubber
Approval: according to VDE 0250 part 606

Dây cáp điện chịu nhiệt CASMO CABLE CASFLON™ 200 UL/cUL Style 1332 , 300V (-65°C to +200°C) Chính Hãng – Giá Tốt Nhất

Dây cáp điện chịu nhiệt CASMO CABLE CASFLON™ 200 UL/cUL Style 1332 , 300V (-65°C [...]

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1569 , 300V (-30°C to +105°C) Chính Hãng – Giá Tốt Nhất

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1569 , 300V (-30°C to +105°C) Chính [...]

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1015 , 600V (-30°C to +105°C) Chính Hãng – Giá Tốt Nhất

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1015 , 600V (-30°C to +105°C) Chính [...]

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1007 , 300V (-20°C to +80°C) Chính Hãng – Giá Tốt Nhất

Dây cáp điện CASMO CABLE CASPLAST™ UL/cUL Style 1007 300V (-20°C to +80°C) Chính Hãng [...]