ÖLFLEX® VFD 2XL with Signal
Multi-listed, flexible VFD cable with a pair for brake or temperature sensor
ÖLFLEX® VFD 2XL – shielded VFD cable for fixed installation or occasional flexing with UL TC-ER certification.
- Suitable for inverter drives of various manufacturers
- Wide application range (NFPA 70/NEC)/ compliance with NFPA 79 for industrial machinery
- EMC-compliant
Benefits
- One common cable for multiple circuits
- Multi-standard certification reduces part varieties and saves costs
- Cost-saving, easy installation due to omission of closed cable systems (suitable for open wiring)
- Longer cable connection possible between converter and drive due to low capacitance design
- UL TC-ER and c(UL) CIC/TC approval
Application range
- Connecting cable between frequency converter and motor
- For fixed installation and applications with occasional movements
- Areas at risk of explosion (class 1 division 2) in accordance with NEC articles 336, 501
- Plant construction
- Industrial machinery and machine tools
Product features
- Oil-resistant according to UL OIL RES I & II
- Flame-retardant according to CSA FT4
UL Vertical-Tray Flame Test - 90°C Wet or Dry; -40°C Cold Bend;
-25°C Cold Impact - Sunlight resistant (UV-resistant); direct burial (can be buried in the ground according to US standards)
Norm references / approvals
- UL TC-ER (exposed run) according to UL 1277
- Class 1 division 2 in accordance with NEC art. 336, 501
- Flexible motor supply cable according to UL
- c(UL) CIC/TC FT4; cRU AWM I/II A/B FT4
- CE (50V – 1kV)
Design
- Fine-wire, tin-plated copper conductor
- Core insulation: XLPE
- Control pair with laminated aluminium film and tin-plated drain wire
- Barrier tape
- Aluminium-coated foil
- Tin-plated copper braiding with drain wire
- Outer sheath: Specially designed thermoplastic elastomer (TPE), black
Classification
- ETIM 5.0 Class-ID: EC000057
- ETIM 5.0 Class-Description: Power cable
Core identification code
- Black with white numbers
Certifications
- USA: UL TC-ER, WTTC, Flexible Motor Supply
Canada: c(UL) CIC/TC FT4, cRU AWM I/II A/B FT4
Conductor design
- Fine wire
Minimum bending radius
- Occasional flexing: 15 x outer diameter
- Fixed installation: 7.5 x outer diameter
Nominal voltage
- UL TC: 600V/2000V
UL Flexible Motor Supply: 1000V
c(UL) CIC/TC: 600V
cRU AWM: 1000V - IEC U0/U: 600/1000 V
Test voltage
- 6000 V
Protective conductor
- G = with GN-YE protective conductor
Temperature range
- Occasional flexing: -25°C to +90°C
Fixed installation: -40°C to +90°C
Article number | Number of cores and mm²/AWG sizes per conductor |
Outer diameter (mm) | Copper index (kg/km) | Weight (kg/km) |
700710 | 4 G 1,5 + (2 x 1,0) | 16.6 | 135408 | 298 |
700711 | 4 G 2,5 + (2 x 1,0) | 17.4 | 196416 | 375 |
700712 | 4 G 4 + (2 x 1,0) | 19.1 | 238.08 | 438 |
700713 | 4 G 6 + (2 x 1,0) | 20.3 | 319.92 | 527 |
700714 | 4 G 10 + (2 x 2,5) | 25 | 496992 | 1027 |
700715 | 4 G 16 + (2 x 2,5) | 28.2 | 749952 | 1347 |
700716 | 4 G 4AWG + (2 x 2,5) | 32 | 992496 | 1674 |
700717 | 4 G 2AWG + (2 x 2,5) | 35.6 | 1,528,176.00 | 2351 |