✅ Cáp Điều Khiển ALANTEK ( 301-FRS025-B02P-3M05 ) 2-pair 2.5MM2 Fire Resistant Shielded Cable, BS 6387 CWZ, Orange

Download : 301-FRS025-B02P-3M05

SHIELDED/UNSHIELDED FIRE RESISTANT CONTROL CABLE

Description
Alantek Fire Resistant Control Cable consists of Bare Copper Conductor
with Mica Tape, XLPE Insulation , with or without Aluminium Foil and
Outer LSZH Jacket
Application
Multipair Control Cable for industrial, alarm, PA and critical system.
Tested in accordance to IEC 60332-3A, IEC 60331, BS 5308 or/and BS
6387 CZW
Colour Code
1 pair : Black, White
> 1 pair : Black, White with numberings (1, 2, 3, 4, cont.)

Cable Properties

Cable Counts Conductor Stranded annealed Copper Mica Tape Insulation
XLPE
Shield Drain Wire Jacket LSZH (Orange colour)
mm2 No./mm Thickness
(mm)
Laminated Aluminium polyester tape Tinned strand copper wire No./mm OD (mm)
±0.6
Unshielded, 1-pair 1.5 7/0.53 2 layer 0.60 Nil Nil 8.3
Unshielded, 1-pair 2.5 7/0.67 2 layer 0.70 Nil Nil 9.5
Unshielded, 2-pair 1.5 7/0.53 2 layer 0.60 Nil Nil 12.8
Unshielded, 2-pair 2.5 7/0.67 2 layer 0.70 Nil Nil 14.7
Shielded, 1pair 1.5 7/0.53 2 layer 0.60 Yes 16/0.2mm 8.5
Shielded, 1pair 2.5 7/0.67 2 layer 0.70 Yes 16/0.2mm 9.7
Shielded, 2pair 1.5 7/0.53 2 layer 0.60 Yes 16/0.2mm 13.0
Shielded, 2pair 2.5 7/0.67 2 layer 0.70 Yes 16/0.2mm 14.9
Unshielded, 1-pair 1.5 7/0.53 2 layer 0.60 Nil Nil 9.3
Unshielded, 1-pair 2.5 7/0.67 2 layer 0.70 Nil Nil 10.5
Unshielded, 2-pair 1.5 7/0.53 2 layer 0.60 Nil Nil 14.4
Unshielded, 2-pair 2.5 7/0.67 2 layer 0.70 Nil Nil 16.4
Shielded, 1pair 1.5 7/0.53 2 layer 0.60 Yes 16/0.2mm 9.5
Shielded, 1pair 2.5 7/0.67 2 layer 0.70 Yes 16/0.2mm 10.7
Shielded, 2pair 1.5 7/0.53 2 layer 0.60 Yes 16/0.2mm 14.6
Shielded, 2pair 2.5 7/0.67 2 layer 0.70 Yes 16/0.2mm 16.6
ShIELDED/UNShIELDED FIRE RESISTANT CONTROL CABLE
STT Part number Mô Tả
1 301-FRU015-E05P-3M05 5PR X1.5MM2 FIRE RESISTANT UNSHIELDED CABLE ORANGE IEC 60331 rl (500m)
2 301-FRS015-E05P-3M05 5PR X 1.5MM2 FIRE RESISTANT SHIELDED CABLE ORANGE IEC 60331 rl (500m)
3 301-FRU015-B01P-3M05 Alantek 1Pair X 1.5MM2 FR Unshielded Cable, Orange IEC 60331 & BS 6387 C W Z rl (500m)
4 301-FRU025-B01P-3M05 Alantek 1Pair X 2.5MM2 FR Unshielded Cable, Orange IEC 60331 & BS 6387 C W Z rl (500m)
5 301-FRS015-B01P-3M05 Alantek 1Pair X 1.5MM2 FR Shielded Cable, Orange IEC 60331 & BS 6387 C W Z rl (500m)
6 301-FRS025-B01P-3M05 Alantek 1Pair X 2.5MM2 FR Shielded Cable, Orange IEC 60331 & BS 6387 C W Z rl (500m)
7 301-FRS015-E01P-3M05 1-pair 1.5MM2 Fire Resistant Shielded Cable, IEC 60331, Orange rl (500m)
8 301-FRS025-E01P-3M05 1-pair 2.5MM2 Fire Resistant Shielded Cable, IEC 60331, Orange rl (500m)
9 301-FRS015-E02P-3M05 2-pair 1.5MM2 Fire Resistant Shielded Cable, IEC 60331, Orange rl (500m)
10 301-FRS025-E02P-3M05 2-pair 2.5MM2 Fire Resistant Shielded Cable, IEC 60331, Orange rl (500m)
11 301-FRS015-B02P-3M05 2-pair 1.5MM2 Fire Resistant Shielded Cable, BS 6387 CWZ, Orange rl (500m)
12 301-FRS025-B02P-3M05 2-pair 2.5MM2 Fire Resistant Shielded Cable, BS 6387 CWZ, Orange rl (500m)
5/5 - (7 bình chọn)