Cáp Điều Khiển Helukabel TOPFLEX® 611-C-PUR | Chính Hãng – Chống Nhiễu Lưới – Cáp Chuyển Động – Motor Cable – Giá Tốt nhất
TOPFLEX® 611-C-PUR |
Motor power supply cable for drag chains 0,6/1 kV, halogen-free,
|
Technical data
- Special-PUR drag chain cable
adapted to DIN VDE 0293, 0295, 0250,
DIN VDE 0285-525-1 / DIN EN 50525-1 - Temperature range
flexing -30°C to +80°C
fixed installation -40°C to +80°C - Nominal voltage
U0/U 600/1000 V - Test voltage
4000 V - Coupling resistance
max. 250 Ohm/km - Insulation resistance
min. 20 MOhm x km - Minimum bending radius
flexing 10x cable Ø
fixed installation 5x cable Ø
Cable structure
- Bare copper conductor, to
DIN VDE 0295 cl.6, extra fine wire,
BS 6360 cl.6, IEC 60228 cl.6 - Core insualtion PP
- Core identification to DIN VDE 0293
black cores with continuous white
numbering - GN-YE conductor
- Cores stranded together with optimal
lay length and stabilising filler - Fleece wrapping facilitates sliding
- Inner sheath of TPE
- Tinned copper braided screen,
approx. 85% coverage - Outer sheath of PUR
- Sheath colour: grey (RAL 7001)
- With meter marking
Properties
- Adhesion-free, extremely abrasion
resistant, halogen-free, resistant to
hydrolysis and microbial attack / Không dính, cực kỳ mài mòn kháng, không halogen, chống thủy phân và tấn công vi sinh vật - Resistant to UV-radiation,
oxygen and ozone / Chống bức xạ UV, oxy và ozon - The materials used during manufacturing
are cadmium-free, contain no silicone
and are free from substances harmful
to the wetting properties of lacquers / Các vật liệu được sử dụng trong quá trình sản xuất không chứa cadmium, không chứa silicone và không có chất gây hại đến tính chất làm ướt của sơn mài
Note
- G = with GN-YE conductor
- For extreme applications extending beyond
standard solutions we recommend that
you request our questionnaire, which has
been especially designed for energy supply
systems. - Please observe applicable installation
regulations for use in energy supply chains. - Unscreened analogue type:
TOPFLEX® 611-PUR
Application
As optimized supply cable for the supply to motors, in particular to DNC motors, servo-motors. These cables are specially designed for use in power drag chains, handling equipment, robotics, tooling machinery, processing and manufacturing machinery. Optimised insulation materials ensure resistance to oils (including mineral oils), greases, coolants, hydraulic fluids as well as many alkalis and solvents. Favourable outer diameters, reduced weights and enhanced torsion characteristics assure the use in multi-layer operations with extremely high continuous bending loads. Suitable for outdoor use.
EMC = Electromagnetic compatibility
To optimize the EMC features we recommend a large round contact of the copper braiding on both ends.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Data sheet
Certificate of compliance
Part no. | No.cores x cross-sec. mm² |
Outer Ø
approx. mm |
Cop. weight kg / km |
Weight
approx. kg / km |
AWG-No. |
---|---|---|---|---|---|
22970 | 4 G 1,5 | 11,3 | 99,0 | 220,0 | 16 |
22971 | 4 G 2,5 | 13,5 | 169,0 | 340,0 | 14 |
22972 | 4 G 4 | 16,0 | 234,0 | 490,0 | 12 |
22973 | 4 G 6 | 17,8 | 316,0 | 680,0 | 10 |
22974 | 4 G 10 | 22,2 | 549,0 | 1035,0 | 8 |
22975 | 4 G 16 | 27,2 | 807,0 | 1460,0 | 6 |
22976 | 4 G 25 | 31,2 | 1169,0 | 1990,0 | 4 |
22977 | 4 G 35 | 35,2 | 1680,0 | 2535,0 | 2 |
22982 | 4 G 50 | 42,5 | 2370,0 | 3360,0 | 1 |
22983 | 4 G 70 | 48,8 | 3257,0 | 4650,0 | 2/0 |
22984 | 4 G 95 | 54,6 | 4060,0 | 6090,0 | 3/0 |
22985 | 4 G 120 | 58,5 | 5231,0 | 7380,0 | 4/0 |