Dây Cáp Điều Khiển Helukabel TROMM-PUR | Chính Hãng – Giá Tốt Nhất
TROMMPUR® |
PUR trailing and control cable, halogen-free |
Technical data
- Special PUR insulation and sheath
adapted to DIN VDE 0250 - Strain bearing support strand
- Temperature range
-40°C to +80°C
(up to +100°C for short periods) - Nominal voltage
up to 1 mm² U0/U 300/500 V
from 1,5 mm² U0/U 450/750 V - Test voltage
up to 1 mm² 2000 V
from 1,5 mm² 2500 V - Breakdown voltage
up to 1 mm² 4000 V
from 1,5 mm² 5000 V - Insulation resistance
min. 20 MOhm x km - Minimum bending radius
10x cable Ø - Radiation resistance
up to 100×106 cJ/kg (up to 100 Mrad)
Cable structure
- Bare copper conductor, to
DIN VDE 0295 cl.6 col.4, extra fine wire,
BS 6360 cl.6, IEC 60228 cl.6 - Core insulation of special PUR
- Support core
- Core identification to DIN VDE 0293
(flexible cables) - Cores stranded in layers with
optimal lay length - Core wrapping with fleece
- Support braiding of synthetic fibres
- Outer sheath of halogen-free PUR
- Sheath colour: orange
Properties
- High flexibility at low temperatures
- Usable for foodstuffs
- Abrasion and tear resistant
- Loadable under torsional stress
Resistant to
- Oils and fats
- Non-alcoholic fuels and kerosene
- Atmospheric influences
- UV-radiation
- Oxygen and ozone
- Microbes and rotting
- Sea and waste water
- Vibrations
Note
- G = with GN-YE conductor
- AWG sizes are approximate equivalent
values. The actual cross section is in mm².
Application
TROMMPUR® has taken the development of the neoprene type cables one step further. It is a robust, all-weather cable, halogen-free, tear and abrasion resistant and suitable for use in drag-chains, in ship docks, on building sites, for conveyor systems, in mining, for tunnels and roadbuilding. For the connecting the ski lift terminal positions to the control unit, surveillance of the joining rods in ski lift cables, as feeder cables for very high currents as for example in pump engineering, mining, locomotive and rail-carriage construction, for oil rig platforms, emergency power generators etc.
CE = Product conforms with Low-Voltage Directive 2014/35/EU.
Downloads
Part no. | No.cores x cross-sec. mm² |
Outer Ø
app. mm |
Cop. weight kg / km |
Weight
app. kg / km |
Breaking strain
ca. kp |
AWG-No. |
---|---|---|---|---|---|---|
26035 | 14 G 0,75 | 16,5 | 154,0 | 320,0 | 250 | 19 |
26036 | 12 G 1 | 17,5 | 115,0 | 300,0 | 500 | 18 |
26037 | 18 G 1 | 23,0 | 173,0 | 480,0 | 500 | 18 |
26038 | 3 G 1,5 | 9,5 | 43,0 | 110,0 | 200 | 16 |
26039 | 5 G 1,5 | 12,5 | 72,0 | 220,0 | 200 | 16 |
26040 | 7 G 1,5 | 15,5 | 101,0 | 270,0 | 250 | 16 |
26041 | 12 G 1,5 | 21,0 | 173,0 | 450,0 | 750 | 16 |
26042 | 18 G 1,5 | 27,0 | 259,0 | 620,0 | 750 | 16 |
26043 | 24 G 1,5 | 30,0 | 346,0 | 850,0 | 750 | 16 |
26044 | 30 G 1,5 | 34,0 | 533,0 | 1100,0 | 750 | 16 |
26045 | 42 G 1,5 | 40,0 | 605,0 | 1600,0 | 750 | 16 |
26046 | 4 G 2,5 | 14,0 | 96,0 | 250,0 | 200 | 14 |
26047 | 5 G 2,5 | 15,0 | 120,0 | 280,0 | 250 | 14 |
26048 | 7 G 2,5 | 18,0 | 168,0 | 360,0 | 300 | 14 |
26049 | 12 G 2,5 | 25,0 | 288,0 | 740,0 | 750 | 14 |
26050 | 24 G 2,5 | 36,0 | 576,0 | 1400,0 | 750 | 14 |
26051 | 30 G 2,5 | 40,0 | 864,0 | 1740,0 | 750 | 14 |
26052 | 36 G 2,5 | 44,0 | 998,0 | 2050,0 | 750 | 14 |
26053 | 7 G 4 | 22,0 | 269,0 | 600,0 | 500 | 12 |
26054 | 4 G 10 | 22,0 | 384,0 | 650,0 | 500 | 8 |
26055 | 4 G 16 | 27,0 | 614,0 | 1100,0 | 500 | 6 |
26059 | 5 G 16 | 34,0 | 768,0 | 1600,0 | 750 | 6 |
26056 | 4 G 25 | 30,0 | 960,0 | 1600,0 | 500 | 4 |
26057 | 4 G 35 | 36,0 | 1344,0 | 2050,0 | 1000 | 2 |
26058 | 4 G 50 | 42,0 | 1920,0 | 2800,0 | 1000 | 1 |