WEIDMULLER ”2466910000” Bộ Nguồn PRO TOP1 120W 12V 10A | Chính Hãng – Giá Tốt Nhất

WEIDMULLER ”2466910000” Bộ Nguồn PRO TOP1 120W 12V 10A | Chính Hãng – Giá Tốt Nhất

DOWNLOADS: PDF data sheet

Version Power supply, switch-mode power supply unit, 12 V
Order No. 2466910000
Type PRO TOP1 120W 12V 10A
GTIN (EAN) 4050118481495
Qty. 1 pc(s).
Availability Delivery date on request
Depth 125 mm
Depth (inches) 4.921 inch
Height 130 mm
Height (inches) 5.118 inch
Net weight 850 g
Width 35 mm
Width (inches) 1.378 inch
Storage temperature -40 °C…85 °C
Operating temperature -25 °C…70 °C
Humidity at operating temperature 5…95 %, no condensation
REACH SVHC Lead 7439-92-1

Input

AC input voltage range 85…277 V AC
Connection system PUSH IN with actuator
Current consumption in relation to the input voltage Voltage type AC
Input voltage 100 V
Input current 2A
Voltage type DC
Input voltage 120 V
Input current 2A
DC input voltage range 80 … 410 V DC
Frequency range AC 45…65 Hz
Input fuse (internal) Yes
Inrush current max. 5 A
Rated input voltage 100 – 240 V AC / 120 – 340 V DC
Recommended back-up fuse 5 A, DI / 6 A, Char. B / 6 A, Char C
Surge protection Varistor

Output

Connection system PUSH IN with actuator
DCL – peak load reserve Boost duration 5 s
Multiple of the rated current 150%
Boost duration 15 ms
Multiple of the rated current 400%
Mains failure bridge-over time > 20 ms @ 115V AC/ 230 VAC
Nominal output current for Unom 10 A @ 60 °C
Output power 120 W
Output voltage 12 V
Output voltage 11…15 V
Output voltage, max. 15 V
Output voltage, min. 11 V
Parallel connection option yes, max 10
Protection against inverse voltage Yes
Ramp-up time ≤ 100 ms
Rated output voltage 12 V DC ± 1 %
Residual ripple, breaking spikes < 50 mVss @ UNenn, Full Load
AC failure bridging time @ Inom > 20 ms @ 230 V AC / > 20 ms @ 115 V AC
Degree of efficiency 90%
Derating > 60°C (2.5% / 1°C)
Earth leakage current, max. 3.5 mA
Housing version Metal, corrosion resistant
MTBF > 1.000.000 h according IEC 1709 (SN29500)
Mounting position, installation notice Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load
Operating temperature -25 °C…70 °C
Power factor (approx.) > 0.85
Short-circuit protection Yes, internal
Surge voltage category III, II
Interference immunity test acc. to EN 55032:2015, EN 55024:2010/A1:2015, EN 55035:2017, EN 61000-3-2:2014, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011, EN 61000-6-4:2007/A1:2011
Noise emission in accordance with EN55032 Class B
Shock resistance IEC 60068-2-27 30 g in all directions
Vibration resistance IEC 60068-2-6 2.3 g (on DIN rail), 4 g (with direct mounting)
Humidity at operating temperature 5…95 %, no condensation
Insulation voltage, input/output 3.5 kV
Pollution severity 2
Protection class I, with PE connection
Surge voltage category III, II
Electrical machine equipment Acc. to EN60204
For use with electronic equipment Acc. to EN50178 / VDE0160
Protection against dangerous shock currents Acc. to VDE0106-101
Protective separation / protection against electrical shock VDE0100-410 / acc. to DIN57100-410
Safety extra-low voltage SELV according to EN 62368-1, PELV according to EN 60204-1
Safety transformers for switch-mode power supplies According to EN 61558-2-16
Conductor cross-section, AWG/kcmil , max. 12
Conductor cross-section, AWG/kcmil , min. 20
Conductor cross-section, flexible , min. 0.5 mm²
Conductor cross-section, rigid , max. 1.5 mm²
Conductor cross-section, rigid , min. 0.5 mm²
Connection system PUSH IN with actuator
Wire connection cross section, flexible (input), max. 2.5 mm²
Conductor cross-section, AWG/kcmil , max. 12
Conductor cross-section, AWG/kcmil , min. 26
Conductor cross-section, flexible , max. 2.5 mm²
Conductor cross-section, flexible , min. 0.2 mm²
Conductor cross-section, rigid , max. 2.5 mm²
Conductor cross-section, rigid , min. 0.2 mm²
Connection system PUSH IN with actuator
Number of terminals 5 (+ + / – – -)
Wire connection method PUSH IN
Wire cross-section, AWG/kcmil , max. 16
Wire cross-section, AWG/kcmil , min. 26
Wire cross-section, solid , max. 1.5 mm²
Wire cross-section, solid , min. 0.14 mm²
Floating contact Yes
LED green/red Green: Operation (failure-free), Flashing green: advance warning I>90%, Green/red flashing: output switched off (switch-off mode), Flashing red: overload/error
Status relay (max. load) Output voltage OK (30 V DC / 1 A)
Approvals ABS BURVER CULUS CULUSEX DNVGL EAC LLOYDSREG RINA TUEV
ROHS Conform
UL File Number Search E258476
ETIM 6.0 EC002540
ETIM 7.0 EC002540
ECLASS 9.0 27-04-07-01
ECLASS 9.1 27-04-07-01
ECLASS 10.0 27-04-07-01
ECLASS 11.0 27-04-07-01
5/5 - (37 bình chọn)