“2569000000” WEIDMULLER Bộ Nguồn PRO TOP1 120W 12V 10A F | Chính Hãng – Giá Tốt Nhất
DOWNLOADS: PDF data sheet
| Version |
Power supply, switch-mode power supply unit, 12 V |
| Order No. |
2569000000 |
| Type |
PRO TOP1 120W 12V 10A F |
| GTIN (EAN) |
4050118579727 |
| Qty. |
1 pc(s). |
| Availability |
Delivery date on request |
| Depth |
125 mm |
| Depth (inches) |
4.921 inch |
| Height |
130 mm |
| Height (inches) |
5.118 inch |
| Net weight |
850 g |
| Width |
35 mm |
| Width (inches) |
1.378 inch |
| Storage temperature |
-40 °C…85 °C |
| Operating temperature |
-25 °C…70 °C |
| Humidity at operating temperature |
5…95 %, no condensation |
| REACH SVHC |
Lead 7439-92-1 |
Input
| AC input voltage range |
85…277 V AC |
| Connection system |
PUSH IN with actuator |
| Current consumption in relation to the input voltage |
Voltage type |
AC |
| Input voltage |
100 V |
| Input current |
2A |
| Voltage type |
DC |
| Input voltage |
120 V |
| Input current |
2A |
| DC input voltage range |
80 … 410 V DC |
| Frequency range AC |
45…65 Hz |
| Input fuse (internal) |
Yes |
| Inrush current |
max. 5 A |
| Rated input voltage |
100 – 240 V AC / 120 – 340 V DC |
| Recommended back-up fuse |
5 A, DI / 6 A, Char. B / 6 A, Char C |
| Surge protection |
Varistor |
Output
| Connection system |
PUSH IN with actuator |
| DCL – peak load reserve |
Boost duration |
5 s |
| Multiple of the rated current |
150% |
| Boost duration |
15 ms |
| Multiple of the rated current |
400% |
| Mains failure bridge-over time |
> 20 ms @ 115V AC/ 230 VAC |
| Nominal output current for Unom |
10 A @ 60 °C |
| Output power |
120 W |
| Output voltage |
12 V |
| Output voltage |
11…15 V |
| Output voltage, max. |
15 V |
| Output voltage, min. |
11 V |
| Parallel connection option |
yes, max 10 |
| Protection against inverse voltage |
Yes |
| Ramp-up time |
≤ 100 ms |
| Rated output voltage |
12 V DC ± 1 % |
| Residual ripple, breaking spikes |
< 50 mVss @ UNenn, Full Load |
| AC failure bridging time @ Inom |
> 20 ms @ 230 V AC / > 20 ms @ 115 V AC |
| Degree of efficiency |
90% |
| Derating |
> 60°C (2.5% / 1°C) |
| Earth leakage current, max. |
3.5 mA |
| Housing version |
Metal, corrosion resistant |
| MTBF |
> 1.000.000 h according IEC 1709 (SN29500) |
| Mounting position, installation notice |
Horizontal on DIN rail TS 35, top and bottom 50 mm clearance for free air flow, 10 mm clearance to neighbouring active subassemblies with full load, 5 mm with passive neighbouring subassemblies, direct row mounting with 90% rated load |
| Operating temperature |
-25 °C…70 °C |
| Power factor (approx.) |
> 0.85 |
| Short-circuit protection |
Yes, internal |
| Surge voltage category |
III, II |
| Interference immunity test acc. to |
EN 55032:2015, EN 55024:2010/A1:2015, EN 55035:2017, EN 61000-3-2:2014, EN 61000-6-1:2007, EN 61000-6-2:2005, EN 61000-6-3:2007/A1:2011, EN 61000-6-4:2007/A1:2011 |
| Noise emission in accordance with EN55032 |
Class B |
| Shock resistance IEC 60068-2-27 |
30 g in all directions |
| Vibration resistance IEC 60068-2-6 |
2.3 g (on DIN rail), 4 g (with direct mounting) |
| Humidity at operating temperature |
5…95 %, no condensation |
| Insulation voltage, input/output |
3.5 kV |
| Pollution severity |
2 |
| Protection class |
I, with PE connection |
| Surge voltage category |
III, II |
| Electrical machine equipment |
Acc. to EN60204 |
| For use with electronic equipment |
Acc. to EN50178 / VDE0160 |
| Protection against dangerous shock currents |
Acc. to VDE0106-101 |
| Protective separation / protection against electrical shock |
VDE0100-410 / acc. to DIN57100-410 |
| Safety transformers for switch-mode power supplies |
According to EN 61558-2-16 |
| Conductor cross-section, AWG/kcmil , max. |
12 |
| Conductor cross-section, AWG/kcmil , min. |
20 |
| Conductor cross-section, flexible , min. |
0.5 mm² |
| Conductor cross-section, rigid , max. |
1.5 mm² |
| Conductor cross-section, rigid , min. |
0.5 mm² |
| Connection system |
PUSH IN with actuator |
| Wire connection cross section, flexible (input), max. |
2.5 mm² |
| Conductor cross-section, AWG/kcmil , max. |
12 |
| Conductor cross-section, AWG/kcmil , min. |
26 |
| Conductor cross-section, flexible , max. |
2.5 mm² |
| Conductor cross-section, flexible , min. |
0.2 mm² |
| Conductor cross-section, rigid , max. |
2.5 mm² |
| Conductor cross-section, rigid , min. |
0.2 mm² |
| Connection system |
PUSH IN with actuator |
| Number of terminals |
4 (++ / –) |
| Wire connection method |
PUSH IN |
| Wire cross-section, AWG/kcmil , max. |
16 |
| Wire cross-section, AWG/kcmil , min. |
26 |
| Wire cross-section, solid , max. |
1.5 mm² |
| Wire cross-section, solid , min. |
0.14 mm² |
| Floating contact |
Yes |
| LED green/red |
Green: Operation (failure-free), Flashing green: advance warning I>90%, Green/red flashing: output switched off (switch-off mode), Flashing red: overload/error |
| Status relay (max. load) |
Output voltage OK (30 V DC / 1 A) |
| Approvals |
 |
| ROHS |
Conform |
| UL File Number Search |
E258476 |
| ETIM 6.0 |
EC002540 |
| ETIM 7.0 |
EC002540 |
| ECLASS 9.0 |
27-04-07-01 |
| ECLASS 9.1 |
27-04-07-01 |
| ECLASS 10.0 |
27-04-07-01 |
| ECLASS 11.0 |
27-04-07-01 |