ADC KRONE (6468 2 060-00) Phiến Cat 5e – HIGHBAND Disconnection Module 8-pr (box of 10pcs) | Chính Hãng – Giá Tốt Nhất

ADC KRONE (6468 2 060-00) Phiến Cat 5e – HIGHBAND Disconnection Module 8-pr (box of 10pcs) | Chính Hãng – Giá Tốt Nhất

KRONE HIGHBAND
8 & 10 Pair Disconnection Modules
Application:
Superior high speed data and voice cross connect modules.
Available in 8 and 10 pair disconnect versions. These modules
enable high speed LAN and WAN systems maximum headroom in
transmission performance.
HIGHBAND utilises the silver plated LSA Plus contact principle.
This is proven technology which has become the ‘industry
standard’ in over 60 countries. The gas tight contacts ensure a
reliable and long lasting connection.
These modules can be either patched, jumpered and used in a
patch by exception configuration.
Technical Specifications:
Environment for use: . . .Indoors or in dry enclosure rated IP54 or greater
Operating temperature range: . . . . . . . . . . . . . .-40ºC to +80ºC
Maximum relative humidity: . . . . . . . . . . .•93% non-condensing
Transmission, performance and reliability:
ŽANSI/EIA/TIA 568A Cat. 5
ŽISO/IEC 11801 Cat. 5
Number of patching cycles: . . . . . . . . . . . . . . . . . . . . . . . . .Ž750
Number of wire reterminations: . . . . . . . . . . . . . . . . . . . . .>200
Wire diameter range for solid and stranded
copper conductors: . . . . . . . . . . .0.40 – 0.65 mm* (26-22 AWG)
Wire insulation
diameter range (PE, PVC): . . . . . . . . . . . . . . . . .0.70 – 1.40 mm
Voltage rating: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .•150 VAC
Insulation resistance: . . . . . . . . . . . . .Ž>500,000 M
W at 500 VDC
Safety: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .UL 1863
Flammability rating of plastic housing: . . . . . . . . . . . . .UL 94 VO
KRONE HIGHBAND
8 & 10 Pair Disconnection Modules
KRONE (Australia) TECHNIQUE PTY LIMITED
ACN 002 047 181
PO Box 335
Wyong NSW 2259
2 Hereford Street
Berkeley Vale NSW 2261
Telephone: (043) 88 4422
Facsimile: (043) 88 4499
Toll Free Help Desk: 1800 801 298
Internet Address: kronehlp@ozemail.com.au
CD5060 Issue 1
* A maximum of 2 equal diameter solid conductors only, of up to 0.5 conductor diameter can be
terminated per slot. Only 1 conductor of stranded wires per slot can be terminated. If any
conductors >0.5 diameter have been terminated, reversal to smaller conductors is no longer possible.
Note: When installing patch cords, ensure that the latch is
located at the bottom of the module and that it clips into
the holes provided.

Part Numbers:
HIGHBAND 8 ………………………………………………6468 2 060-00
HIGHBAND 10 …………………………………………….6468 2 061-00
Also available:
Switching Modules
HIGHBAND 16………………………………………………6468 2 080-00
HIGHBAND 20……………………………………………...6468 2 081-00

Approvals:
ACA Compliant
UL Certified Category 5

Product Documentation

Product Information

5/5 - (23 bình chọn)